Refrigeration - Remote Condenser Models
Remote condenser models have additional
installation needs.
The correct remote condenser fan and coil must be
connected to the ice making head. Liquid and
discharge tubing connections are on the back of
the ice machine cabinet. Pre-charged tubing kits
are available in several lengths to accommodate
most installations. Order the one that just exceeds
the length needed for the installation.
The kit numbers are:
RTE10
RTE25
RTE40
RTE75
There are limits as to how far away from the ice
machine and where the remote condenser can be
located. See the next page for those limits.
The correct condenser must be used.
Ice Machine Model Condenser Model
F0822R-1 ERC111-1
F1222R-32, F1222R-3 ERC311-32
N0622R-1, N0822R-1 ERC111-1
N0922R-32, N1222R-3 ERC311-32
N1322R-32 ERC311-32
Note: A headmaster is required for all remote
condenser systems. Prior condensers did not have
a headmaster. New head / old condenser retrofits
can use headmaster kit KPFHM. See chart below
for applications.
Prior Head Prior Condenser New Head
NME654R ERC101 N0622R
FME804R ERC101 F0822R
NME954R ERC151 N0922R
FME1204R ERC151 F1222R
NME1254R ERC201 N1322R
FME1504R ERC201 F1522R
Do not reuse condenser coils contaminated with
mineral oil (used with R-502 for example). They will
cause compressor failure and will void the
warranty.
September 2009
Page 9
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual