Initial Start Up
1. Turn the water supply on.
2. Switch the electrical power on. Confirm voltage
is correct for the model.
3. Push and release the On button. The machine
will start in about two minutes.
4. Soon after starting, air cooled models will begin
to blow warm air out the back of the cabinet
and water cooled models will drain warm water
from the condenser drain tube. Remote
models will be discharging warm air from the
remote condenser. After about 5 minutes, ice
will begin to drop into the bin or dispenser.
5. Check the machine for unusual rattles. Tighten
any loose screws, be sure no wires are rubbing
moving parts. Check for tubes that rub.
6. Fill out the warranty registration form and either
file it on line or mail it.
7. Notify the user of the maintenance
requirements and whom to call for service.
September 2009
Page 20
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
Change De-Scale Notification Interval
This feature is accessible only from standby
(Status Light Off).
1. Press and hold Clean button for 3 seconds.
This starts the Time to Clean Adjustment State
and displays the current time to clean setting.
2. Press the clean button repeatedly to cycle
through the 4 possible settings:
•
1 year (8760 hours)
•
0 (disabled)
•
4 months (2920 hrs)
•
6 months (4380 hours) (default)
3. Push Off to confirm the selection.