Installation
For The Plumber
Begin by planning the installation and obtaining the
needed supplies:
3
8
" soft copper tubing
3
4
" rigid drain tubing
3
4
" FPT fitting for bin/reservoir drain connection
1
2
" FPT fitting for condenser drain connection
3
8
" FPT fitting for water cooled condenser inlet
connection
1. Connect cold potable water to the
3
8
" male flare
at the back of the cabinet. A water filter and hand
shut off valve is recommended. Flush the water
line prior to connecting to the ice machine.
If water cooled, connect a separate water inlet line
to the water cooled condenser inlet fitting. It should
also have a hand shut off valve.
A loop of copper tubing may be used between the
ice machine and the water supply. This will allow
the ice machine to be pulled out from its installed
location without disconnecting the water line. No
back-flow preventer should be needed in the inlet
potable water line because provision for that is
incorporated in this N.S.F. listed product (the water
valve outlet is above the reservoir wall and cannot
siphon).
2. Connect a drain tube to each drain connection
(water cooled drain must be separate).
3. Route the drain tubes to the building drain
receptacle.
SCE275
January 2003
Page 5
CONFORM TO ALL LOCAL CODES
Plumbing Connections,
Water Cooled Shown
Water Cooled Inlet
Water Cooled Drain
Reservoir & Bin
Drain
Potable Water Inlet
Drain Receptacle
Field Supplied Filter