Scotsman SCE275 Bedienungsanleitung Seite 34

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 33
SCE275
January 2003
Page 34
Removal and Replacement: Thermistors
There is a thermistor to sense reservoir water
temperature and another to sense compressor
discharge temperatures. If the AutoIQ Controller
senses a fault with the thermistors, both diagnostic
indicator lights will be glowing continuously.
Disconnect electrical power before beginning.
1. Remove the grills from the front of the cabinet.
2. Push and hold the Off button to shut the
machine Off.
3. Remove the hood.
4. Remove the bin.
5. Locate the thermistor attached to the discharge
line of the compressor. Remove the insulation
covering the thermistor and un-clip it from the
discharge line.
6. Unplug the thermistor from the wire harness by
AutoIQ Controller.
7. Plug the new set into the AutoIQ Controller.
8. Route the thermistor to the discharge tube of the
compressor and attach it to the discharge line in
the same place as the original.
9. Re-cover the thermistor with insulation.
10. At the upper left of the machine, un-plug the
water pump and water level sensor.
11. Lift up the water pump mounting plate and pull
the water hose off the water pump. Remove the
water pump and water level sensor and set aside.
12. Remove the water thermistor from the
discharge hose of the water pump.
13. Unplug the thermistor from the wire harness.
14. Insert the new thermistor into the discharge
hose. Do not allow the body of the thermistor to
contact the hose opposite of the mounting hole.
15. Secure thermistor with cable tie.
16. Plug thermistor into wire harness.
17. Return water pump and water level sensor to
its normal position. Reconnect power and ground
wires.
18. Return bin and hood to their normal positions.
19. Reconnect electrical power and push the
Freeze button to restart the machine.
20. Return the grills to their normal position.
Electrical shock
hazard.
Electrical shock can
cause personal injury.
Disconnect power before
beginning to service
Seitenansicht 33