FOR THE INSTALLER: Remote Condenser
SPECIFICATIONS: REMOTE CONDENSER
RTE25 Precharged line set, 25’. R-404A
RTE40 Precharged line set, 40’. R-404A
* Two machines on one condenser require a fan relay kit.
Icemaker Nameplate Located On Back Panel
Serial Plate Located Behind Front Panel
Installation Limitations:
This ice system is designed to be installed indoors,
in a controlled environment:
Min. Max.
Air Temperature 50
0
F100
0
F
Water Temperature 40
0
F100
0
F
Water Pressure 20 psi 80 psi
Voltage 5% +10%
(Compared to the nameplate)
The temperature limitations do not apply to the
remote condenser. It will work between -20
degrees F, and 120 degrees F.
Operating the machine outside of the limitations is
misuse and can void the warranty.
Scotsman Ice Systems are designed and
manufactured with the highest regard for safety
and performance. They meet or exceed the
standards of UL, NSF, and CSA.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any part and/or other components not
specifically approved by Scotsman.
Scotsman reserves the right to make design
changes and/or improvements at any time.
19
7
8
"
23
13
16
"
Model Use with Basic Electrical
RCE651-32 1 FME1500R 208-230/60/1
ERC201-32 SAME 208-230/60/1
RCE652-32 1 or 2 FME1500Rs* 208-230/60/1
ERC402-32 SAME 208-230/60/1
ERC DIMENSIONS
Model A B F G
ERC201
33
3
8
" 10
3
4
" 16
3
4
" 11
5
8
"
ERC402
43
3
8
" 10
3
4
" 21
3
4
" 16
5
8
"
FME1500R