Discharge temperature sensor.
Thermistor attached to the discharge line near the compressor. Reported temperature
used by the controller to determine end-of-cycle-fan-off-delay time. If discharge
temperature exceeds a preset maximum, controller will shut the machine off.
Note: Controller will operate machine in a default mode with thermistors disconnected from the
controller. Diagnostic code #5 or 7 will be displayed during that time.
Component Indicator Light Table
System Indicator Light ON
Condenser Fan or Liquid Line
Valve
Fan Motor Powered or LLV open
Water Pump Pump Motor Powered
Purge Valve Purge Valve Opens
Inlet Water Solenoid Valve Inlet Water Valve Opens
Hot Gas Hot Gas Valve Opens
Compressor Contactor Contactor Closes
Ready to Harvest Water contacting ice thickness sensor probe
Sump Empty Open between mid sensor and common
Sump Full Closed between top probe and mid probe
Curtain Switch Curtain open