Prodigy Cuber System Information
Overall System Type:
•
Refrigeration: Mechanical, either air cooled, water cooled or remote cooled.
•
Water System: Inlet water solenoid valve fills reservoir once per cycle. Purge solenoid
valve opens to discharge some reservoir water once per cycle.
•
Control System: Electronic
•
Harvest cycle sensor: Conductivity probe
•
Water full/empty sensor: Conductivity probe
•
Bin Control: Curtain Switch
•
Ice type: Unified
•
Harvest system: Hot gas defrost with mechanical assist
Electrical Components:
•
Compressor
•
Contactor
• Water Pump
• Inlet Water Solenoid Valve
• Purge or purge Valve
• Fan Motor(s)
• Fan motor pressure control
• High pressure cut out – certain AC models only
• Harvest Assist Solenoid(s)
• Hot Gas Valve(s)
• Controller
•
Transformer – 12v AC for the controller only
•
Water Level Sensor
•
Ice Thickness Sensor
•
Curtain Switch(es)