Maintenance: Scale Removal
Note: Following this procedure will reset the
de-scale and sanitize light.
1. Remove front panel.
2. Push and release the Off button.
3. Remove ice from bin or dispenser.
4. Turn the water supply to the ice machine OFF.
5. Drain the water and evaporator by
disconnecting the leg of the hose connected to
the water sensor and draining it into the bin.
Return the hose to its original position
6. Remove the water reservoir cover.
7. Mix a solution of 8 ounces of Scotsman Clear
One Scale Remover and 3 quarts of 95-115
degree F. potable water.
8. Pour the scale remover solution into the
reservoir. Use a small cup for pouring.
9. Push and release the Clean button: the auger
drive motor and light are on, C is displayed and
the De-scale light blinks. After 20 minutes the
compressor will start.
10. Operate the machine and pour the scale
remover into the reservoir until it is all gone.
Keep the reservoir full. When all the scale
remover solution has been used, turn the water
supply back on. After 20 minutes of ice making
the compressor and auger motor will shut off.
11. Turn the water supply to the ice machine OFF
12. Drain the water reservoir and evaporator by
disconnecting the leg of the hose connected to
the water sensor and draining it into the bin or
a bucket. Return the hose to its original
position. Discard or melt all ice made during
the previous step.
13. To sanitize the water system, mix a locally
approved sanitizing solution. An example of a
sanitizing solution is mixing one ounce of liquid
household bleach and two gallons of 95 – 115
degree F. water.
14. Pour the sanitizing solution into the reservoir.
15. Push and release the On button.
16. Switch the water supply to the ice machine on.
17. Operate the machine for 20 minutes.
18. Push and release the Off button.
19. Wash the reservoir cover in the remaining
sanitizing solution.
20. Return the reservoir cover to its normal
position.
21. Melt or discard all ice made during the
sanitizing process.
22. Wash the inside of the ice storage bin with the
sanitizing solution.
23. Push and release the On button.
24. Return the front panel to its original position
and secure with the original screws.
Note: If the reservoir is not kept full during step 10,
the scale removal process will be incomplete and
the de-scale light will remain on.
September 2009
Page 32
N0422, F0522, N0622, F0822, N0922, F1222, N1322, F1522
Air, Water or Remote Service Manual
Ice machine scale remover
contains acids. Acids can
cause burns.
If concentrated cleaner
comes in contact with skin,
flush with water. If swallowed,
do NOT induce vomiting.
Give large amounts of water
or milk. Call Physician
immediately. Keep out of the
reach of children.