Specifications
These ice machines are designed to be installed
indoors, in a controlled environment. They can
operate satisfactorily under a wide variety of
conditions. Do NOT operate the machine in
temperatures it has not been designed for. Do
NOT operate the machine above or below the
voltage limits for the particular model. Do NOT
operate the machine with too little or too much
water pressure.
Operational Limits
Minimum Maximum
Air Temperature 50
o
F. 100
o
F.
Water Temperature 40
o
F. 100
o
F.
Water Pressure 20 psi 80 psi
Voltage (60 Hz model) 198 253
Voltage (50 Hz model) 207 253
Inlet water flow required is 2.7 GPM.
A stacking kit, for
like models, is KSCME6-LG-B
Voltage note: The control system transformer in
the control box of this ice machine has two primary
taps, one for 208 volt power and one for 240 volt
power. The machine ships with the power supply
connected to the 208 volt tap. Change to the 240
volt tap when the voltage supplied to the unit is
greater than 229 volts
All models will fit a standard, 48" wide Scotsman
Ice Storage Bin. Some examples are BH900,
BH1100, BH1300, BH1600. There may be other
bins that can be used, check Scotsman’s sales
literature for application information. Slope front
bins must have an internal baffle like the BH900.
Baffle must be approximately in the position shown
in the diagram on page 5.
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.
Dateplates on the ice machine contain charge and
electrical requirements. Always go by the dataplate
information. The table below is for reference.
Model Number
Model
Series
Dimensions
W" x D" x H"
(w/o bin)
Basic
Electrical
Condenser
Type
Minimum
Circuit
Ampacity
Maximum
Fuse
Size
Refrigerant
Charge
(R-404A)
CME1356AS-32 A thru E 48 ½ x 24 x 28 208-230/60/1 Air Cooled 26.7 30 64 ounces
CME1356WS-32 A thru E same 208-230/60/1 Water Cooled 23.9 30 62 ounces
CME1356WS-32 F same 208-230/60/1 Water Cooled 23.9 30 58 ounces
CME1356AS-3 A thru E same 208-230/60/3 Air Cooled 17.8 20 64 ounces
CME1356WS-3 A thru E same 208-230/60/3 Water Cooled 14.9 20 62 ounces
CME1356WS-3 F same 208-230/60/3 Water Cooled 14.9 20 58 ounces
CME1356AS-6 A thru E same 230/50/1 Air Cooled 26.7 30 64 ounces
CME1356WS-6 A thru E same 230/50/1 Water Cooled 23.9 30 62 ounces
CME1356WS-6 F same 230/50/1 Water Cooled 23.9 30 58 ounces
CME1656AS-32 A thru D same 208-230/60/1 Air Cooled 26.7 30 64 ounces
CME1656WS-32 A thru E same 208-230/60/1 Water Cooled 23.9 30 62 ounces
CME1656WS-32 F same 208-230/60/1 Water Cooled 23.9 30 58 ounces
CME1656AS-3 A thru E same 208-230/60/3 Air Cooled 17.8 20 64 ounces
CME1656WS-3 A thru E same 208-230/60/3 Water Cooled 14.9 20 62 ounces
CME1656WS-3 F same 208-230/60/3 Water Cooled 14.9 20 58 ounces
CME1656AS-6 A thru E same 230/50/1 Air Cooled 26.7 30 64 ounces
CME1656WS-6 A thru E same 230/50/1 Water Cooled 23.9 30 62 ounces
CME1656WS-6 F same 230/50/1 Water Cooled 23.9 30 58 ounces