Sonar Service Diagnosis
Step 2: If it is a sonar problem, check the
board.
– 12 volts to board.
If not, check the transformer.
– When ice is called for, the
relay contacts are CLOSED.
Check the relay on the board. COM to NO should be closed.
If they are open, REPLACE THE BOARD - NOT THE
TRANSDUCER