Additional Maintenance: Water Level Sensor
Water Level Sensor:
Clean the lenses inside the water level sensor.
1. Remove front panel.
2. Push and hold the Off button until the ice
machine stops.
3. Unplug the wire harness from the sensor.
4. Remove the reservoir cover.
5. Lift up on cover and pull float from float stem.
6. Unsnap sensor from cover. Remove the sensor
from its installed position.
7. Remove dust cover.
8. Wipe lenses clean with a cotton swab.
Reverse to reassemble.
Note: Be CERTAIN that the sensor has be
properly reassembled. Wire connection must be in
the position shown in the photos.
CME306 & CME456
January 2000
Page 28
Dust Cover
Lenses
Water Level
Sensor
Float Stem