Scotsman CME810 Spezifikationen Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 50
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
System Location
Limitations:
Distance: Limited to the maximum length of a
single pre-charged tubing kit, 75 feet.
Condensing Unit Elevation over Ice Making
Section: 35 feet.
Note: Elevations greater
than 20 feet require
installation of a suction line
trap at the 20 foot mark.
Ice Making Section
Elevation over Condensing
Unit: 15 feet.
Line Routing:
·
Allowed: One rise after a drop.
·
Allowed: One drop after a rise.
·
Not Allowed: More than one rise after a drop
·
Not Allowed: More than one drop after a rise.
Eclipseä 600, 800, 1000
April 2002
Page 12
22.87"
17.15"
40.35"
Condensing Unit Distance Schematic
Max Rise:
35 Feet
Max Drop:
15 Feet
Max Length -
Limit of Line Set
Condensing
Unit Located
Below Ice
Machine
Condensing
Unit Located
Above Ice
Machine
S-Trap
Seitenansicht 11