Operational Characteristics: CME506R
Cycle Times (Minutes):
System Pressures (PSIG):
Refrigerant Charge
•
224 ounces of R-404A
Typical Compressor Amps
•
Freeze: 10 - 12
•
Harvest: 12- 13
Typical Harvest Ice Weight
•
6.5 - 7 lb.
Note: Beginning with CME506R - E series, the
refrigeration system uses 2 internally equalized
thermostatic expansion valves.
CME506R, 656R, 806R: AutoIQ Cubers
March 2002
Page 32
0
o
F. condenser air 70
o
F. indoor air,
55
o
F. water
90
o
F. condenser air 90
o
F. indoor
air, 70
o
F. water
Freeze 21 - 24 25 - 28
Harvest 1.5 - 2.5 1 - 2
0
o
F. condenser air 70
o
F. indoor air,
55
o
F. water
90
o
F. condenser air 90
o
F. indoor
air, 70
o
F. water
Suction: End of Freeze 34 - 36 36 - 38
Suction: Peak in Harvest 100 - 110 105 - 115
Discharge: 5 minutes into Freeze 230 - 250 250 - 270
Discharge: Minimum in Harvest 200 210