Specifications
This ice machine is designed to be installed
indoors, in a controlled environment. It will operate
satisfactorily under a wide variety of conditions. Do
NOT operate the machine in temperatures it has
not been designed for. Do NOT operate the
machine above or below the voltage limits for the
particular model. Do NOT operate the machine
with too little or too much water pressure.
Operational Limits
Minimum Maximum
Air Temperature 50
o
F. 100
o
F.
Water Temperature 40
o
F. 100
o
F.
Water Pressure 20 psi 80 psi
Voltage (60 Hz model) 198 253
Voltage (50 Hz model) 207 253
Inlet water flow required is 2.7 GPM.
All models will fit a standard, 30" wide Scotsman
Ice Storage Bin. Some examples are:
BH550
HTB555
Note: Slope front bins must have an internal baffle.
Scotsman BH550 and HTB555 have the required
baffle. Baffle must be approximately in the position
shown in the diagram on page 5.
In addition, there may be other bins that can be
used, check Scotsman’s sales literature for
application information.
Kits:
BH800 bin: Add kit KBT23
BH900 bin: Add kit KBT22
ID200 or ID250 Dispenser: Add adapter kit
KBT44. Do not deploy the CME1056’s
thermostat.
Lancer 30” wide dispenser. Add adapter kit
KSTAT-MD
Cornelius ED200 dispenser requires adapter
kit from Cornelius. Do not deploy the
CME1056’s thermostat.
Other combinations may be available. See
Scotsman product literature for more
information.
Stacking two CME1056s together requires
stacking kit: KSCME6-MD (cannot stack any
other model with a CME1056).
Scotsman reserves the right to make design
changes and/or improvements at any time.
Specifications and designs are subject to change
without notice.
Scotsman assumes no liability or responsibility of
any kind for products manufactured by Scotsman
that have been altered in any way, including the
use of any parts and/or other components not
specifically approved by Scotsman.
CME1056
May 2002
Page 2
Model Number
Dimensions
W"xD"xH"
(w/o bin)
Basic
Electrical
Condenser
Type
Minimum
Circuit
Ampacity
Maximum
Fuse Size
Refrigeran
t Charge
(R-404A)
CME1056AS-32F 30½x24x28 208-230/60/1 Air Cooled 18.75 20 44 ounces
CME1056WS-32F same 208-230/60/1 Water Cooled 17.25 20 28 ounces
CME1056AS-3F same 208-230/60/3 Air Cooled 13.63 15 44 ounces
CME1056WS-3F same 208-230/60/3 Water Cooled 12.13 15 28 ounces
CME1056AS-6F same 230/50/1 Air Cooled 44 ounces
CME1056WS-6F same 230/50/1 Water Cooled 28 ounces