Scotsman C1848R Bedienungsanleitung Seite 18

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 26
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 17
Adjustments
Bridge Thickness - For A Service Tech Only
1. Push and hold Off till the machine stops.
2. Remove evaporator cover.
3. Remove curtain.
4. Use a box wrench and rotate the bridge
thickness adjustment screw in 1/8 turn
increments CW to increase bridge thickness.
Rotate CCW to decrease bridge thickness.
Caution: Do not make the bridge too thin or the
machine will not harvest properly. Bridge thickness
adjustments are not covered by warranty.
5. Return curtain to its normal position.
6. Push and release the On button. Check next
harvest of ice. Repeat steps 1-6 if needed.
Water purge setting
The water purge is factory set to the automatic
position, suitable for most water conditions. The
setting can be changed to one of 5 manual settings
or left on automatic.
purge
setting
1-
Minimum
2-
Moderate
3 - Standard
4-
Heavy
5-
Maximum
A - Automatic
Water
Type
RO water
or
equivalent
Factory
Setting for
typical water
High TDS
water
Any with
conductivity not
less than 10
microSiemens/cm
To set:
1. Switch the machine OFF by holding the Off
button in until a number or the letter A shows
on the display.
2. Press and release the On button repeatedly
until the number on the display corresponds to
the desired setting.
3. Press and release the Off switch again to
return to the normal control state.
November 2006
Page 17
C1448, C1848, C2148
Remote Condenser Models - User Manual
Ice Bridge Thickness Measurement
Too Big
Too Small
Just Right,
Small Cube
1/8 - 3/16"
bridge
Just Right,
Medium Cube
Ice Thickness Sensor
Seitenansicht 17