IntroductionTo the owner or user: This service manual isintended to provide you, and the maintenance orservice technician, with the information needed
After Utility Connections1. Level the cabinet, use the leg levelers on theend of the legs to adjust the cabinet height. (Legsshould have been installe
Component LocationMany components are serviceable from the frontwithout removing the side panels.Behind the front panel:•• Water pump•• Inlet water va
Initial Start UpAfter the final check list has been gone through,the ice machine may be started up.1. Open the water shut off valve; the inlet waterva
Initial Start UpNote: If the first batch of cubes are not all uniformdiscs, some ice machine cleaner should be addedto the reservoir.1. After ice has
Maintenance, Cleaning and SanitizingCleaning Schedule:••Scrub the outside of the cabinet once a weekwith soap and water.••Sanitize the bin interior on
Cleaning: Ice Machine Water SystemDissolve and Remove Minerals:1. Remove front panel.2. Move the ICE/OFF/WASH switch to OFF.3. Remove the splash guard
Refrigeration Schematic:Freeze Cycle:From the compressor, hot discharge gas ispumped to the condenser, either air or watercooled.At the condenser, hea
Harvest Cycle:The ice maker continues to freeze the water intoice until the ice next to the ice size thermostatprobe has become thick enough to force
Technical CharacteristicsTypical Cycle Time ••16 minutes @ 90oF. air and 70oF. water; 13 minutes @ 70oF. air and 50oF. waterTypical Harvest Ice Weight
Service Diagnosis: SYMPTOM POSSIBLE CAUSE PROBABLE FIXNo ice is made, nothing operates Unit off, due to no power Restore powerUnit off, due to ICE/OFF
SpecificationsInformation regarding Model Number, SerialNumber, Ampacity and Maximum Fuse Size arelocated on the nameplate of the ice machine. Themode
SYMPTOM POSSIBLE CAUSE PROBABLE FIXNo ice compressor is operating No cooling due to low refrigerantchargeLocate leak, recover remainingrefrigerant, re
Service Diagnosis: SYMPTOM POSSIBLE CAUSE PROBABLE FIXIce is made, but will not harvest Will not harvest due to hot gasvalve not opening.Check for vol
Removal and ReplacementIce Size Thermostat:Before replacing the ice size thermostat, it shouldbe positively determined that it is at fault.1. Disconne
Removal and ReplacementWater PumpThe pump provides the force to move the waterfrom the reservoir to the freezing surface. Thepump does not need oil, b
Removal and Replacement: Refrigeration SystemGeneral:••Scotsman recommends that any work on therefrigeration system only be done when it iscertain tha
For The Installer: Environmental LimitationsThe ice machine must be installed indoors in acontrolled environment.Minimum MaximumAir Temp 550F. 1000F.W
InstallationWaterThe water supply for this ice machine has been incontact with many materials since it fell from thesky as rain. All rain is slightly
Capillary TubeBin ThermostatBracketFasten CabinetsTogether At BackWith Straps &Screws.Routing HoleStackingInstallation: Ice Storage BinAssembly:1.
Installation: SLD150 Hotel DispenserAssemblyThe ice machine must be placed onto the top ofthe dispenser, and the bin thermostat capillarytube routed i
Installation: Scotsman IS or RS DispenserAssembly:The assembly of the ice machine onto thedispenser requires two additional parts: an adapterkit and a
InstallationFor The PlumberSupply:Screw the 3/8" male flare (fitting shipped inpackage inside cabinet) into the 1/4" FPT fitting atthe back
InstallationFor The ElectricianThis unit must be on a separate 115 volt AC 60cycle single phase power supply. The maximumfuse size for this circuit is