INTRODUCTION
To the owner or user: The service manual you are
reading is intended to provide you, and the
maintenance or service technician, with the
information needed to install, start up, clean,
maintain, and service this ice system.
This product contains 2 separate ice making
systems in one cabinet.
NME1854 & FME2404
January 2000
Page 1
Table of Contents
FOR THE INSTALLER ······································ Page 2
FOR THE INSTALLER: Environmental Limitations ························ Page 3
FOR THE INSTALLER ······································ Page 4
FOR THE INSTALLER: Location ································· Page 5
FOR THE PLUMBER ······································· Page 6
FOR THE ELECTRICIAN ····································· Page 7
FOR THE INSTALLER ······································ Page 8
START UP ············································ Page 9
COMPONENT DESCRIPTION ·································· Page 10
COMPONENT DESCRIPTION ·································· Page 11
COMPONENT DESCRIPTION: Control Box ··························· Page 12
ELECTRICAL SEQUENCE ···································· Page 13
OPERATION: Performance ···································· Page 14
OPERATION: Water ······································· Page 15
OPERATION: Refrigeration ···································· Page 16
CLEANING and SANITATION ·································· Page 17
SENSOR MAINTENANCE ···································· Page 18
BEARING MAINTENANCE ···································· Page 19
AIR COOLED CONDENSER MAINTENANCE ·························· Page 20
AUGER MAINTENANCE ····································· Page 21
SERVICE DIAGNOSIS: ······································ Page 22
SERVICE DIAGNOSIS ······································ Page 23
CONTROL SYSTEM DIAGNOSTICS ······························ Page 24
REMOVAL AND REPLACEMENT: Water Reservoir & Bin Controls ··············· Page 25
REMOVAL AND REPLACEMENT: Bearing And Breaker ···················· Page 26
REMOVAL AND REPLACEMENT: Auger ···························· Page 27
REMOVAL AND REPLACEMENT: Water Seal ·························· Page 28
REMOVAL AND REPLACEMENT: Evaporator ·························· Page 29
REMOVAL AND REPLACEMENT: Gearmotor ·························· Page 30
REMOVAL AND REPLACEMENT: Fans ····························· Page 31
REFRIGERATION SERVICE ··································· Page 32
This manual was printed on recycled paper. Keep
it for future reference.
Note the Warning symbol where it appears, it
marks a possible hazard.
Seitenansicht 0
1 2 3 4 5 6 ... 31 32

Inhaltsverzeichnis

Seite 1 - NME1854 & FME2404

INTRODUCTIONTo the owner or user: The service manual you arereading is intended to provide you, and themaintenance or service technician, with theinfo

Seite 2

COMPONENT DESCRIPTIONControl Box: Contains the electrical controls thatoperate the machine.High Pressure Cut Out Switch: An automatic resetswitch sens

Seite 3

COMPONENT DESCRIPTIONEvaporator: A refrigerated vertical tube filled withwater and containing a water seal and auger.Auger: A solid stainless steel do

Seite 4

COMPONENT DESCRIPTION: Control BoxContactor: A definite purpose contactorconnecting the compressor and the remotecondenser fan motor to the power supp

Seite 5

NME1854 & FME2404January 2000Page 13ELECTRICAL SEQUENCEThere are 7 indicator lights on the control board:·WTR-OK (Water OK). Green. Normal =Glowin

Seite 6

OPERATION: PerformanceTypical Low Side Pressure·Air Cooled: 34 - 38 PSIG·Water Cooled: 32 PSIGTypical Discharge Pressure·Air Cooled: 220 - 275 PSIG·Wa

Seite 7

OPERATION: WaterWater enters the machine through the 3/8" maleflare at the rear of the cabinet, splits into twoseparate lines, flows to each wate

Seite 8

NME1854 & FME2404January 2000Page 16OPERATION: RefrigerationBeginning at the compressor, refrigerant iscompressed into a high temperature gas. The

Seite 9

CLEANING and SANITATIONA Scotsman Ice System represents a sizable investment of time and money in any company’s business. Inorder to receive the best

Seite 10

1. The bin control uses devices that sense light,therefore they must be kept clean enough so thatthey can “see”. At least twice a year, remove thebin

Seite 11

BEARING MAINTENANCECheck each top evaporator bearing at least twotimes per year.A. Check the bearing by:·removing the ice chute cover·unscrewing the i

Seite 12

FOR THE INSTALLERThe FME2404 and theNME1854 are modular flakersdesigned to fit the followingScotsman storage bins:·B90 and extensions (with bintop KBT

Seite 13

NME1854 & FME2404January 2000Page 20Clean or replace the air filters regularly.Clean each air cooled condenser. Use a vacuumcleaner or coil cleane

Seite 14

NME1854 & FME2404January 2000Page 21In some areas the water supply to the ice machinewill have a great deal of minerals in it, and that willresult

Seite 15

NME1854 & FME2404January 2000Page 22SERVICE DIAGNOSIS:No ice is made, nothing operates Unit off due to no power Restore PowerUnit off due to maste

Seite 16

SERVICE DIAGNOSISSymptom Possible Cause Probable CorrectionWater Leak Drain plugged up Clean out drainTubing cracked Replace tubingCondensation on dra

Seite 17

NME1854 & FME2404January 2000Page 24CONTROL SYSTEM DIAGNOSTICSThe control system consists of:·Control Board·Water Sensor·Ice Sensors·High Pressure

Seite 18

WATER RESERVOIR1. Shut off water supply.2. Remove front panel.3. Remove reservoir cover.4. Disconnect water inlet tube from reservoir inletfitting.5.

Seite 19

NME1854 & FME2404January 2000Page 26REMOVAL AND REPLACEMENT: Bearing And BreakerNote: Removal of the auger, water seal, evaporatorand gear motor m

Seite 20

NME1854 & FME2404January 2000Page 27To Remove the Auger:Turn off the water to the machine, and unclip theevaporator drain hose, pull it down and d

Seite 21

NME1854 & FME2404January 2000Page 28To Remove the Water Seal:(Assuming all steps to remove the auger have beenperformed.)1. The gear motor/evapora

Seite 22

NME1854 & FME2404January 2000Page 29To Replace the Evaporator:(Assuming all the steps for removal of the thrustbearing, breaker, auger, and water

Seite 23

Installation Limitations:This ice system is designed to be installed indoors,in a controlled environment:Min MaxAir Temperature 500F 1000FWater Temper

Seite 24

NME1854 & FME2404January 2000Page 30REMOVAL AND REPLACEMENT: GearmotorCOVER &OUTPUT GEARASSEMBLYCENTRIFUGALSWITCHAUGER DRIVE MOTORROTOR BEARIN

Seite 25

REMOVAL AND REPLACEMENT: FansNME1854 & FME2404January 2000Page 31Removing Condenser Fan Motor Assembly1. Remove the top panel.2. Unplug the two fa

Seite 26

NME1854 & FME2404January 2000Page 32REFRIGERATION SERVICEGeneral: This ice machine uses R-404A refrigerantand polyolester oil. Do NOT use mineral

Seite 27

FOR THE INSTALLERLocation:After uncrating and inspection the unit is ready forinstallation. Install the machine in a location whereit has enough space

Seite 28

NME1854 & FME2404January 2000Page 5FOR THE INSTALLER: LocationALLOW ROOMFOR AIRCIRCULATIONAND SERVICEACCESSDO NOT STACK ANYTHING INFRONT OF THE MA

Seite 29

FOR THE PLUMBERCONFORM TO ALL APPLICABLE CODESWater InletAir Cooled Models: Connect to a water supplythat is cold and potable. Use38" O.D. copper

Seite 30

FOR THE ELECTRICIANCONFORM TO ALL APPLICABLE CODESConnect electrical power to the leads in thejunction box at the rear of the machine.Check the namepl

Seite 31

FOR THE INSTALLERFinal Check List______1. Is the ice system installed indoors in alocation where the air and watertemperatures are controlled, and whe

Seite 32

START UPPre-Start Inspection1. Remove the front and side service panels.2. Check that any shipping blocks have beenremoved.3. Inspect the interior of