Scotsman AF300 Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Eiswürfelmacher Scotsman AF300 herunter. Scotsman AF300 Service manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 37
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Page 1
Page 1
SCOTSMAN EUROPE - FRIMONT SPA
Via Puccini, 22 - 20010 Pogliano M.se - Milano - Italy
Tel. +39-02-93960.1 (Aut. Sel.)- Telefax +39-02-93550500
Direct Line to Service & Parts:
Phone +39-02-93960350 - Fax +39-02-93540449
Website: www.scotsman-ice.com
ISO 9001 - Cert. n. 0080
SERVICE MANUAL
AF 80
AF 100
AF 200
AF 20
AF 30
S
Electronic flakers
with storage
MS 1000.73 REV. 05/2009
Seitenansicht 0
1 2 3 4 5 6 ... 36 37

Inhaltsverzeichnis

Seite 1 - Electronic flakers

Page 1Page 1SCOTSMAN EUROPE - FRIMONT SPAVia Puccini, 22 - 20010 Pogliano M.se - Milano - ItalyTel. +39-02-93960.1 (Aut. Sel.)- Telefax +39-02-9355050

Seite 2

Page 10Page 10Start Electric power cons.Amps Kwh per 24 HRBasic electr. Amps Watts Nr. of wires Amps fuseSPECIFICATIONSModel Cond. unit Finish C

Seite 3 - ELECTRONIC FLAKER MODEL AF 80

Page 11Page 11SPECIFICATIONSice making capacityELECTRONIC FLAKER MODEL AF 30Important operating requirements:MIN MAX- Air temperature 10°C (50°F) 40

Seite 4 - AF80 - MACHINE SPECIFICATIONS

Page 12Page 12S. Steel 1/2 70 Kg.Start Electric power cons.Amps Kwh per 24 HRBasic electr. Amps Watts Nr. of wires Amps fuseSPECIFICATIONSModel

Seite 5 - SPECIFICATIONS

Page 13Page 13GENERAL INFORMATION AND INSTALLATIONA. INTRODUCTIONThis manual provides the specifications and thestep-by-step procedures for the instal

Seite 6 - * A 15°C water temperature

Page 14Page 14All SCOTSMAN ice machines are supplied fromthe factory completely pre-wired and require onlyelectrical power connections to the wire cor

Seite 7

Page 15Page 1511. Has the Manufacturer’s registration cardbeen filled in properly? Check for correct modeland serial number against the serial plate a

Seite 8

Page 16Page 1621LNCOMPRESSOR910111213345678CONTACTOR COILGEAR MOTORFAN MOTORELECTRONICCARDRELAYSTRIACRESETS E N S O R SDATA PROCESSORWATERLEVELGEAR MO

Seite 9 - ELECTRONIC FLAKER MODEL AF 20

Page 17Page 17FIG. 221LNCOMPRESSOR910111213345678CONTACTOR COILGEAR MOTORFAN MOTORELECTRONICCARDRELAYSTRIACRESETS E N S O R SWATERLEVELGEAR MOTOR

Seite 10 - AF20 - MACHINE SPECIFICATIONS

Page 18Page 18FIG. 421LNCOMPRESSOR910111213345678CONTACTOR COILGEAR MOTORFAN MOTORELECTRONICCARDRELAYSTRIACRESETS E N S O R SWATERLEVELGEAR MOTOR

Seite 11 - ELECTRONIC FLAKER MODEL AF 30

Page 19Page 19FIG. 521LNCOMPRESSOR910111213345678CONTACTOR COILGEAR MOTORFAN MOTORELECTRONICCARDRELAYSTRIACRESETS E N S O R SWATERLEVELGEAR MOTOR

Seite 12 - AF30 - MACHINE SPECIFICATIONS

Page 2Page 2TABLE OFCONTENTSTable of contents page 2Specifications AF 80 3Specifications AF 100 5Specifications AF 200 7Specifications AF 20 9

Seite 13

Page 20Page 20NOTE. The ICE LEVEL CONTROL(INFRA-RED SYSTEM) is independent ofthe temperature however, the reliability ofits detection can be affecte

Seite 14

Page 21Page 21WATER CIRCUITThe water enter in the machine through the waterinlet fitting which incorporates a strainer and it islocated at the rear si

Seite 15 - °C (40°F) or above 35°C

Page 22Page 22FIG. 621LNCOMPRESSOR910111213345678CONTACTOR COILGEAR MOTORFAN MOTORELECTRONICCARDRELAYSTRIACRESETS E N S O R SWATERLEVELGEAR MOTOR

Seite 16 - OPERATING INSTRUCTIONS

Page 23Page 23directly fitted in the gear case through which itdrives - in counter clockwise rotation at a speedof 9.5 r.p.m. - the freezer auger bein

Seite 17

Page 24Page 24REFRIGERANT METERING DEVICE:capillary tubeREFRIGERANT CHARGE (R 134 A)air cooled water cooledAF 80 310 gr 310 grAF 100 420 gr xxxxxA

Seite 18

Page 25Page 25A. EVAPORATOR TEMPERATURE SENSORThe evaporator sensor probe is inserted into itstube well, which is welded on the evaporatoroutlet line,

Seite 19 - DATA PROCESSOR

Page 26Page 26JP3JP260/70°CTESTJP1SYENTRANSFORMERTRANSFORMEREVAPORATOR SENSOR SOCKETCONDENSER SENSOR SOCKETDRIVE MOTOR SENSOR SOCKETWATER SENSORSOCKET

Seite 20

Page 27Page 27In the ice breaker it is housed the top bearingwhich is made of two rolls bearings positioned towithstand the auger axial and radial loa

Seite 21 - PRINCIPLE OF OPERATION

Page 28Page 28NOTE. Read the instructions thoroughlybefore performing any of the followingadjustment or removal and replacement pro-cedure.A. ADJUSTEM

Seite 22

Page 29Page 292. Unloose the three screws securing the plasticcover to the gear motor speed sensor housingand remove it.3. Unloose the two screws secu

Seite 23

Page 3Page 3SPECIFICATIONSice making capacityELECTRONIC FLAKER MODEL AF 80NOTE. With the unit in “built-in” conditions, the ice production is graduall

Seite 24 - °C ambient temperature)

Page 30Page 30NOTE. It is good practice to replace the waterseal assy and both the top and the bottombearings any time the auger is removed.To facilit

Seite 25

Page 31Page 316. To install the replacement condenser followthe above steps in reverse.NOTE. Thoroughly evacuate the system toremove moisture and non

Seite 26 - °C after 10 min of operation

Page 32Page 326. Trace the water regulating valve capillarytube and unsolder its end from the refrigerant linethen remove it from the unit.NOTE. It is

Seite 27

Page 33Page 33WIRING DIAGRAMAIR AND WATER COOLED230/50-60/1GV - YELLOW GREENB - WHITEG - GREYN - BLACKA - BLUEM - BROWNV - GREEN

Seite 28

Page 34Page 34SYMPTON POSSIBLE CAUSE SUGGESTED CORRECTIONUnit will not run Blown fuse in P.C.Board Replace fuse & check for cause ofNo LED lighted

Seite 29

Page 35Page 35SYMPTON POSSIBLE CAUSE SUGGESTED CORRECTIONWet ice Ambinet temperature too high Move unit to cooler locationHigh water level in the free

Seite 30

Page 36Page 36MAINTENANCE AND CLEANING INSTRUCTIONA. GENERALThe periods and the procedures for maintenanceand cleaning are given as guides and are not

Seite 31

Page 37Page 373. Shut close the water shutoff valve on waterline.4. Remove the top panels to gain access to thewater reservoir.5. Remove the float res

Seite 32 - 0.5-1.0 mm

Page 4Page 4Start Electric power cons.Amps Kwh per 24 HRBasic electr. Amps Watts Nr. of wires Amps fuseSPECIFICATIONSModel Cond. unit Finish Com

Seite 33 - WIRING DIAGRAM

Page 5Page 5SPECIFICATIONSice making capacityELECTRONIC FLAKER MODEL AF 100Important operating requirements:MIN MAX- Air temperature 10°C (50°F) 40°

Seite 34 - SERVICE DIAGNOSIS

Page 6Page 6Start Electric power cons.Amps Kwh per 24 HRBasic electr. Amps Watts Nr. of wires Amps fuseSPECIFICATIONSModel Cond. unit Finish Com

Seite 35

Page 7Page 7SPECIFICATIONSice making capacityELECTRONIC FLAKER MODEL AF 200NOTE. The daily ice-making capacity is directly related to the condenser ai

Seite 36

Page 8Page 8AF 200 AS Air 100*AF 200 WS Water 580*S. Steel 3/8 32 Kg.Start Electric power cons.Amps Kwh per 24 HRBasic electr. Amps Watts Nr. of wi

Seite 37

Page 9Page 9SPECIFICATIONSice making capacityELECTRONIC FLAKER MODEL AF 20Important operating requirements:MIN MAX- Air temperature 10°C (50°F) 40°C